{"id":9160,"date":"2026-11-26T10:19:17","date_gmt":"2026-11-26T02:19:17","guid":{"rendered":"https:\/\/xzfastener.com\/?p=9160"},"modified":"2026-11-26T10:19:19","modified_gmt":"2026-11-26T02:19:19","slug":"fastener-magnetic-particle-inspection-report-scope","status":"publish","type":"post","link":"https:\/\/xzfastener.com\/de\/fastener-magnetic-particle-inspection-report-scope\/","title":{"rendered":"Magnetic Particle Inspection for Bolting: Purchasing the Right Scope"},"content":{"rendered":"<style>.xz-purchase-guide{width:100%;max-width:900px;margin:0 auto;line-height:1.8;overflow-wrap:anywhere;box-sizing:border-box}.xz-purchase-guide h2{font-size:26px;line-height:1.4;margin:28px 0 14px}.xz-purchase-guide p{margin:0 0 18px}.xz-purchase-guide li{margin:8px 0}.xz-purchase-guide a{text-decoration:underline}@media(max-width:767px){.xz-purchase-guide{padding-right:44px}.xz-purchase-guide h2{font-size:22px}.xz-purchase-guide ul{padding-left:20px}}<\/style>\n<div class=\"xz-purchase-guide\">\n<p>A magnetic particle inspection line on a bolting purchase order needs more detail than the abbreviation MT. The buyer needs to know what material and area are examined, what result will be delivered and how the inspected pieces remain identifiable through packing.<\/p>\n<h2>Confirm that the method suits the material<\/h2>\n<p>Magnetic particle examination depends on a suitable ferromagnetic material. Do not transfer an inspection instruction from an alloy-steel stud order to an austenitic stainless order without technical review. A grade name alone also does not define the complete examination procedure. Provide the actual material specification, supply condition and component drawing to the qualified inspection provider.<\/p>\n<h2>Define the examined component and stage<\/h2>\n<p>Specify whether the requested record covers raw stock, an intermediate blank or the finished fastener. These are different scopes. Identify threads, transitions, ends and any inaccessible regions on the drawing. Engineering and the inspection provider should agree the examination sequence in relation to machining, heat treatment and coating, including whether later operations require further examination.<\/p>\n<h2>Make disposition part of the order<\/h2>\n<p>Name the examination practice, approved procedure, acceptance reference and responsible reviewing party. State the coverage and sampling basis explicitly. A note saying \u201cno cracks\u201d does not resolve how every observed indication is classified. Keep interpretation with qualified personnel and contractual acceptance with the designated authority. If rework is proposed, require a documented disposition and any required re-examination rather than accepting an unrecorded touch-up.<\/p>\n<h2>Close the identification chain<\/h2>\n<p>Request the part and revision, heat and manufacturing lot, examined quantities, individual identifiers where applicable, method and procedure references, findings and release status. Agree any requirements for demagnetization and residual-field verification with the responsible engineer; do not assume these are included in a bare test price. Check how identification is preserved if marks are removed or pieces are transferred to another processing facility.<\/p>\n<h2>Prepare the enquiry<\/h2>\n<p>Provide a drawing with the required areas marked, the material condition and project acceptance document. Ask for inspection scope and report details as separate quotation lines so a lower price does not conceal missing coverage.<\/p>\n<p>Send the drawing revision, material specification, quantities and destination to <a href=\"https:\/\/xzfastener.com\/de\/home\/contact-us\/\">XZ Fastener for a quotation review<\/a>. Identify any material inspection report, dimensional report, batch traceability, EN 10204 3.1\/3.2 or third-party report required. The applicable scope, issuing parties and approval requirements need agreement before the order.<\/p>\n<p>Related purchasing guidance: <a href=\"https:\/\/xzfastener.com\/de\/individual-fastener-serial-number-inspection-register\/\">Linking individually identified parts to inspection records<\/a>.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A magnetic particle inspection line on a bolting purchase order needs more detail than the abbreviation MT. The buyer needs to know what material and area are examined, what result will be delivered and how the inspected pieces remain identifiable through packing. Confirm that the method suits the material Magnetic particle examination depends on a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[109],"tags":[],"class_list":["post-9160","post","type-post","status-publish","format-standard","hentry","category-technical-guides"],"acf":[],"_links":{"self":[{"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/posts\/9160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/comments?post=9160"}],"version-history":[{"count":1,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/posts\/9160\/revisions"}],"predecessor-version":[{"id":9161,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/posts\/9160\/revisions\/9161"}],"wp:attachment":[{"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/media?parent=9160"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/categories?post=9160"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xzfastener.com\/de\/wp-json\/wp\/v2\/tags?post=9160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}