{"id":6717,"date":"2025-12-11T17:39:47","date_gmt":"2025-12-11T09:39:47","guid":{"rendered":"https:\/\/xzfastener.com\/?p=6717"},"modified":"2026-06-18T17:40:49","modified_gmt":"2026-06-18T09:40:49","slug":"ce-compliance-for-structural-fasteners-what-project-buyers-should-confirm","status":"publish","type":"post","link":"https:\/\/xzfastener.com\/fr\/ce-compliance-for-structural-fasteners-what-project-buyers-should-confirm\/","title":{"rendered":"Conformit\u00e9 CE pour les fixations structurelles\u00a0: ce que les acheteurs de projets doivent confirmer"},"content":{"rendered":"<p>CE compliance for structural fasteners is not only a label issue. It affects whether bolts, nuts, washers, and complete bolting assemblies can be accepted on European construction projects.<\/p>\n\n\n\n<p>Many problems start with a simple misunderstanding. A buyer asks for \u201cM20 grade 8.8 structural bolts.\u201d The supplier quotes standard bolts. Later, the project asks for CE-marked EN 15048 or EN 14399 assemblies, Declaration of Performance, marking, and traceability.<\/p>\n\n\n\n<p>At that point, price and delivery schedule may both change.<\/p>\n\n\n\n<p>For project buyers, CE compliance should be confirmed before quotation, not before shipment.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What CE Compliance Means for Structural Fasteners<\/h2>\n\n\n\n<p>CE marking shows that a construction product has declared performance under the applicable European system. For structural fasteners, this usually means the product must follow the relevant harmonized EN standard and be supported by required documents.<\/p>\n\n\n\n<p>It is not a general quality logo. It is tied to product performance, factory control, marking, and documentation.<\/p>\n\n\n\n<p>For structural bolting projects, buyers should confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Applicable EN standard<\/li>\n\n\n\n<li>CE marking requirement<\/li>\n\n\n\n<li>D\u00e9claration de performance<\/li>\n\n\n\n<li>Identification du fabricant<\/li>\n\n\n\n<li>Product or assembly marking<\/li>\n\n\n\n<li>Tra\u00e7abilit\u00e9 des lots<\/li>\n\n\n\n<li>Documents de contr\u00f4le<\/li>\n\n\n\n<li>Exigences en mati\u00e8re d'\u00e9tiquette d'emballage<\/li>\n<\/ul>\n\n\n\n<p>Sourcing d'acheteurs <a href=\"https:\/\/xzfastener.com\/fr\/products-category\/high-strength-fasteners\/\">attaches \u00e0 haute r\u00e9sistance<\/a> should treat these requirements as part of the product specification.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EN 15048 contre EN 14399<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Confirm the Connection Type First<\/h3>\n\n\n\n<p>The first question is whether the connection is non-preloaded or preloaded. The project design should answer this.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Norme<\/th><th>Type de fixation<\/th><th>Utilisation typique<\/th><th>Focus acheteur<\/th><\/tr><\/thead><tbody><tr><td>EN 15048<\/td><td>Assemblages de boulonnage structurel non pr\u00e9contraints<\/td><td>Structural joints without controlled preload<\/td><td>SB assembly, marking, DoP, traceability<\/td><\/tr><tr><td>EN 14399<\/td><td>Assemblages de boulonnage structurel \u00e0 haute r\u00e9sistance pour le pr\u00e9chargement<\/td><td>Preloaded structural connections<\/td><td>HV\/HR system, washer matching, preload control<\/td><\/tr><tr><td>EN 1090 project execution<\/td><td>Steel and aluminum structure execution<\/td><td>Installation and inspection control<\/td><td>Tightening method, site acceptance<\/td><\/tr><tr><td>Sp\u00e9cification du projet<\/td><td>Job-specific requirement<\/td><td>Bridges, buildings, towers, plants<\/td><td>Final approval rules<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Do not replace EN 14399 with EN 15048 unless the project engineer approves it. Same diameter and grade do not mean the same structural function.<\/p>\n\n\n\n<p>For common supply categories, buyers can review <a href=\"https:\/\/xzfastener.com\/fr\/products-category\/standard-fasteners\/\">attaches standards<\/a> before confirming whether structural compliance is required.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Project Buyers Should Check<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Complete Assembly Requirement<\/h3>\n\n\n\n<p>Structural fasteners are often checked as assemblies. A bolt alone may not be enough. The nut and washer must match the system.<\/p>\n\n\n\n<p>Confirmez\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bolt type and standard<\/li>\n\n\n\n<li>Nut grade and standard<\/li>\n\n\n\n<li>Washer type, hardness, and coating<\/li>\n\n\n\n<li>Assembly marking<\/li>\n\n\n\n<li>Lot number<\/li>\n\n\n\n<li>Manufacturer mark<\/li>\n\n\n\n<li>Original packaging condition<\/li>\n<\/ul>\n\n\n\n<p>Pour une planification compl\u00e8te du produit, les acheteurs peuvent consulter l'int\u00e9gralit\u00e9 <a href=\"https:\/\/xzfastener.com\/fr\/home\/products\/\">produits de fixation<\/a> gamme.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Marking and Packaging<\/h3>\n\n\n\n<p>Marking matters during site inspection. If the carton label, product marking, and document batch number do not match, the goods may be delayed or rejected.<\/p>\n\n\n\n<p>Check the packaging for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>CE-related label information<\/li>\n\n\n\n<li>R\u00e9f\u00e9rence standard<\/li>\n\n\n\n<li>Type d'assemblage<\/li>\n\n\n\n<li>Size and grade<\/li>\n\n\n\n<li>Quantit\u00e9<\/li>\n\n\n\n<li>Num\u00e9ro de lot<\/li>\n\n\n\n<li>Identification du fabricant<\/li>\n\n\n\n<li>Coating or finish description<\/li>\n<\/ul>\n\n\n\n<p>Do not open and repack structural assemblies casually. Repacking can create traceability problems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Declaration of Performance<\/h3>\n\n\n\n<p>The Declaration of Performance should match the product, standard, manufacturer, and intended use. It should not be treated as a generic certificate.<\/p>\n\n\n\n<p>Before shipment, confirm that the DoP matches:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exigence EN 15048 ou EN 14399<\/li>\n\n\n\n<li>Type de produit<\/li>\n\n\n\n<li>Gamme de tailles<\/li>\n\n\n\n<li>Performance characteristics<\/li>\n\n\n\n<li>Manufacturer information<\/li>\n\n\n\n<li>CE marking details<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Rev\u00eatement et protection contre la corrosion<\/h2>\n\n\n\n<p>Surface finish can affect both compliance and installation. Structural fasteners may be supplied plain, zinc plated, hot-dip galvanized, zinc flake coated, or with another approved system.<\/p>\n\n\n\n<p>Coating affects:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>R\u00e9sistance \u00e0 la corrosion<\/li>\n\n\n\n<li>Ajustement du filetage<\/li>\n\n\n\n<li>Nut running behavior<\/li>\n\n\n\n<li>Torque or preload control<\/li>\n\n\n\n<li>Protection des emballages<\/li>\n\n\n\n<li>Inspection requirements<\/li>\n<\/ul>\n\n\n\n<p>Pour les projets ext\u00e9rieurs ou sensibles \u00e0 la corrosion, comparez <a href=\"https:\/\/xzfastener.com\/fr\/products-category\/various-coated-fasteners\/\">diverses attaches enduites<\/a> avant de finaliser la finition.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Erreurs courantes des acheteurs<\/h2>\n\n\n\n<p>\u00c9vitez ces probl\u00e8mes\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Asking only for \u201cstructural bolts\u201d without EN standard.<\/li>\n\n\n\n<li>Ordering by grade only, such as 8.8 or 10.9.<\/li>\n\n\n\n<li>Mixing bolts and nuts from different sources.<\/li>\n\n\n\n<li>Requesting CE documents after production is finished.<\/li>\n\n\n\n<li>Ignoring original packaging and label rules.<\/li>\n\n\n\n<li>Confusing non-preloaded and preloaded assemblies.<\/li>\n\n\n\n<li>Approving coating without checking thread fit.<\/li>\n\n\n\n<li>Using standard stock bolts for CE-required structural projects.<\/li>\n<\/ul>\n\n\n\n<p>For special dimensions, coating zones, or drawing-based assemblies, use <a href=\"https:\/\/xzfastener.com\/fr\/products-category\/custom-non-standard-fasteners\/\">fixations non standard sur mesure<\/a> and confirm CE-related requirements before production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">RFQ Checklist for CE Structural Fasteners<\/h2>\n\n\n\n<p>Une demande de prix claire doit inclure\u00a0:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Article de la demande de prix<\/th><th>Que pr\u00e9ciser<\/th><\/tr><\/thead><tbody><tr><td>Norme du projet<\/td><td>EN 15048, EN 14399, EN 1090, or project spec<\/td><\/tr><tr><td>Connection type<\/td><td>Non-preloaded or preloaded<\/td><\/tr><tr><td>Product assembly<\/td><td>Bolt, nut, washer details<\/td><\/tr><tr><td>Taille<\/td><td>Diam\u00e8tre, longueur, pas de filetage, longueur de filetage<\/td><\/tr><tr><td>Note<\/td><td>Property class or project grade<\/td><\/tr><tr><td>Rev\u00eatement<\/td><td>Plain, HDG, zinc flake, zinc plated, or specified finish<\/td><\/tr><tr><td>Documents<\/td><td>DoP, MTC, inspection report, coating report<\/td><\/tr><tr><td>Marquage<\/td><td>CE-related marking, manufacturer mark, batch number<\/td><\/tr><tr><td>Emballage<\/td><td>Original labels, lot separation, carton marks<\/td><\/tr><tr><td>Contr\u00f4le<\/td><td>Pre-shipment check and site acceptance requirements<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>If washers are part of the assembly, review <a href=\"https:\/\/xzfastener.com\/fr\/fastener-type\/washers\/\">produits de laveuse<\/a> and confirm hardness, dimensions, and coating compatibility.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conseil final<\/h2>\n\n\n\n<p>CE compliance for structural fasteners should be checked at the RFQ stage. Buyers should confirm the EN standard, connection type, complete assembly, marking, DoP, coating, traceability, and packaging before placing the order.<\/p>\n\n\n\n<p>For European structural projects, the cheapest bolt is not useful if the inspector rejects the documents. The correct standard and document package protect the project schedule.<\/p>","protected":false},"excerpt":{"rendered":"<p>CE compliance for structural fasteners is not only a label issue. It affects whether bolts, nuts, washers, and complete bolting assemblies can be accepted on European construction projects. Many problems start with a simple misunderstanding. A buyer asks for \u201cM20 grade 8.8 structural bolts.\u201d The supplier quotes standard bolts. Later, the project asks for CE-marked [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[479],"tags":[505],"class_list":["post-6717","post","type-post","status-publish","format-standard","hentry","category-fastener-knowledge-library","tag-certificates-reports-compliance"],"acf":[],"_links":{"self":[{"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/posts\/6717","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/comments?post=6717"}],"version-history":[{"count":1,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/posts\/6717\/revisions"}],"predecessor-version":[{"id":6718,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/posts\/6717\/revisions\/6718"}],"wp:attachment":[{"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/media?parent=6717"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/categories?post=6717"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xzfastener.com\/fr\/wp-json\/wp\/v2\/tags?post=6717"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}