{"id":6573,"date":"2021-04-08T18:00:50","date_gmt":"2021-04-08T10:00:50","guid":{"rendered":"https:\/\/xzfastener.com\/?p=6573"},"modified":"2026-06-17T18:02:36","modified_gmt":"2026-06-17T10:02:36","slug":"ce-requirements-for-structural-fasteners-in-european-projects","status":"publish","type":"post","link":"https:\/\/xzfastener.com\/zh\/ce-requirements-for-structural-fasteners-in-european-projects\/","title":{"rendered":"\u6b27\u6d32\u9879\u76ee\u7ed3\u6784\u7d27\u56fa\u4ef6\u7684 CE \u8981\u6c42"},"content":{"rendered":"<p>For European steel construction projects, structural fasteners are not treated like ordinary hardware. If a bolt assembly is used in a regulated structural application, buyers must check whether CE marking, Declaration of Performance, and the correct EN standard apply.<\/p>\n\n\n\n<p>This is where many importers make mistakes.<\/p>\n\n\n\n<p>They ask for \u201c8.8 structural bolts\u201d or \u201cDIN bolts for steel structure,\u201d but the European project may require CE-marked assemblies under EN 15048 or EN 14399. A standard bolt may look similar, but if the marking, documentation, and assembly control are missing, it may not be accepted on site.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What CE Marking Means for Structural Fasteners<\/h2>\n\n\n\n<p>CE marking for construction products shows that the manufacturer has declared product performance according to the relevant European rules. It is not simply a quality logo. It is linked to the applicable harmonized standard, factory production control, testing, traceability, and required documents.<\/p>\n\n\n\n<p>For structural bolting, buyers should confirm whether the project requires:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>CE-marked structural bolt assemblies<\/li>\n\n\n\n<li>\u7ee9\u6548\u58f0\u660e<\/li>\n\n\n\n<li>Correct EN standard<\/li>\n\n\n\n<li>\u6279\u6b21\u8ffd\u6eaf<\/li>\n\n\n\n<li>\u5236\u9020\u5546\u6807\u8bc6<\/li>\n\n\n\n<li>Assembly-level supply, not random mixed parts<\/li>\n\n\n\n<li>Inspection and test documentation<\/li>\n<\/ul>\n\n\n\n<p>Buyers comparing structural fastener options can review available <a href=\"https:\/\/xzfastener.com\/zh\/products-category\/high-strength-fasteners\/\">\u9ad8\u5f3a\u5ea6\u7d27\u56fa\u4ef6<\/a> \u548c <a href=\"https:\/\/xzfastener.com\/zh\/products-category\/standard-fasteners\/\">\u6807\u51c6\u7d27\u56fa\u4ef6<\/a> \u5728\u51c6\u5907\u8be2\u4ef7\u4e4b\u524d\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EN 15048 \u4e0eEN 14399<\/h2>\n\n\n\n<p>European structural fasteners are commonly divided by whether the connection is non-preloaded or preloaded.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u6807\u51c6\u578b<\/th><th>\u5e94\u7528\u7c7b\u578b<\/th><th>\u5178\u578b\u7684\u4e70\u5bb6\u62c5\u5fe7<\/th><\/tr><\/thead><tbody><tr><td>EN 15048<\/td><td>\u975e\u9884\u7d27\u7ed3\u6784\u87ba\u6813\u7ec4\u4ef6<\/td><td>Correct assembly marking and documentation<\/td><\/tr><tr><td>EN 14399<\/td><td>\u7528\u4e8e\u9884\u8f7d\u7684\u9ad8\u5f3a\u5ea6\u7ed3\u6784\u87ba\u6813\u7ec4\u4ef6<\/td><td>Suitability for controlled preload<\/td><\/tr><tr><td>Project drawings<\/td><td>May specify additional requirements<\/td><td>Must be checked before ordering<\/td><\/tr><tr><td>National annex or project spec<\/td><td>May add local rules<\/td><td>Do not rely on product name alone<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The key word is \u201cassembly.\u201d Structural fasteners for CE-marked supply are often controlled as bolt, nut, and washer assemblies. Buying bolts from one source, nuts from another, and washers from a third may create compliance and traceability problems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Buyers Should Check Before Ordering<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u4ea7\u54c1\u6807\u51c6<\/h3>\n\n\n\n<p>Ask the supplier which standard the fasteners follow. Do not accept only \u201cstructural bolt\u201d as a complete description.<\/p>\n\n\n\n<p>RFQ\u5e94\u6ce8\u660e\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>EN 15048 or EN 14399 requirement<\/li>\n\n\n\n<li>\u87ba\u6813\u5c3a\u5bf8\u548c\u957f\u5ea6<\/li>\n\n\n\n<li>\u5f3a\u5ea6\u7b49\u7ea7\u6216\u6027\u80fd\u7b49\u7ea7<\/li>\n\n\n\n<li>\u87ba\u6bcd\u548c\u57ab\u5708\u7684\u5339\u914d\u8981\u6c42<\/li>\n\n\n\n<li>\u8868\u9762\u5149\u6d01\u5ea6<\/li>\n\n\n\n<li>Required CE marking and DoP<\/li>\n\n\n\n<li>\u5305\u88c5\u548c\u6807\u7b7e\u8981\u6c42<\/li>\n<\/ol>\n\n\n\n<p>For full project lists, buyers can also review the broader <a href=\"https:\/\/xzfastener.com\/zh\/home\/products\/\">\u7d27\u56fa\u4ef6\u4ea7\u54c1<\/a> \u8303\u56f4\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Marking and Labeling<\/h3>\n\n\n\n<p>Structural fastener packaging should allow the buyer, contractor, and inspector to identify the goods clearly.<\/p>\n\n\n\n<p>Labels should include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4ea7\u54c1\u6807\u51c6<\/li>\n\n\n\n<li>\u5c3a\u5bf8<\/li>\n\n\n\n<li>Grade<\/li>\n\n\n\n<li>Manufacturer or batch identification<\/li>\n\n\n\n<li>Assembly type<\/li>\n\n\n\n<li>\u6570\u91cf<\/li>\n\n\n\n<li>\u8868\u9762\u5149\u6d01\u5ea6<\/li>\n\n\n\n<li>Traceability information<\/li>\n\n\n\n<li>CE-related information where required<\/li>\n<\/ul>\n\n\n\n<p>Poor labeling can delay receiving, inspection, and project approval.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Surface Finish and Coating Requirements<\/h2>\n\n\n\n<p>European structural fasteners may be supplied with different finishes depending on the project environment. Common options include plain, zinc plated, hot-dip galvanized, zinc flake, or other specified coatings.<\/p>\n\n\n\n<p>For outdoor steel structures, corrosion protection must be confirmed carefully. Hot-dip galvanizing can improve protection, but coating thickness may affect thread fit. Zinc flake coatings may be preferred in some high-strength assemblies where controlled thickness and corrosion resistance matter.<\/p>\n\n\n\n<p>\u4e70\u5bb6\u53ef\u4ee5\u8bc4\u8bba <a href=\"https:\/\/xzfastener.com\/zh\/products-category\/various-coated-fasteners\/\">\u6d82\u5c42\u7d27\u56fa\u4ef6<\/a> \u5f53\u8010\u8150\u8680\u662f\u9879\u76ee\u8981\u6c42\u7684\u4e00\u90e8\u5206\u65f6\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Mistakes in European Project Sourcing<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Mistake 1: Ordering Only by DIN or ISO<\/h3>\n\n\n\n<p>DIN or ISO dimensions may not satisfy CE requirements for structural assemblies. European projects may require EN 15048 or EN 14399 compliance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mistake 2: Treating CE Marking as Optional<\/h3>\n\n\n\n<p>If the fastener is covered by the applicable construction product requirements and project specification, CE documentation may be mandatory for acceptance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mistake 3: Mixing Assembly Components<\/h3>\n\n\n\n<p>Structural bolt, nut, and washer assemblies should be matched and traceable. Random mixing may create inspection issues.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mistake 4: Missing the Declaration of Performance<\/h3>\n\n\n\n<p>A certificate alone may not replace the required Declaration of Performance. Buyers should request the correct document before shipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mistake 5: Ignoring Project-Specific Rules<\/h3>\n\n\n\n<p>Some projects may add requirements for coating, testing, third-party inspection, packing, or local approval.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">RFQ Checklist for CE-Related Structural Fasteners<\/h2>\n\n\n\n<p>Before placing an order, confirm the following:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>\u8be2\u4ef7\u9879\u76ee<\/th><th>\u9700\u8981\u6307\u5b9a\u4ec0\u4e48<\/th><\/tr><\/thead><tbody><tr><td>\u6807\u51c6\u578b<\/td><td>EN 15048, EN 14399, or project requirement<\/td><\/tr><tr><td>\u7ec4\u88c5<\/td><td>Bolt, nut, washer set details<\/td><\/tr><tr><td>\u5c3a\u5bf8<\/td><td>Diameter, length, thread pitch, washer size<\/td><\/tr><tr><td>Grade<\/td><td>Property class or project-specified strength<\/td><\/tr><tr><td>\u5b8c\u6210<\/td><td>Plain, HDG, zinc flake, or specified coating<\/td><\/tr><tr><td>\u6587\u6863<\/td><td>DoP, MTC, inspection report, CE-related documents<\/td><\/tr><tr><td>\u53ef\u8ffd\u6eaf\u6027<\/td><td>Batch number and manufacturer identification<\/td><\/tr><tr><td>\u5305\u88c5<\/td><td>Original packing, labels, carton marks<\/td><\/tr><tr><td>\u68c0\u67e5<\/td><td>Project, third-party, or pre-shipment inspection needs<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>If a project requires non-standard dimensions or special assemblies, buyers should use <a href=\"https:\/\/xzfastener.com\/zh\/products-category\/custom-non-standard-fasteners\/\">\u5b9a\u5236\u975e\u6807\u7d27\u56fa\u4ef6<\/a> and confirm compliance requirements before production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6700\u7ec8\u5efa\u8bae<\/h2>\n\n\n\n<p>CE requirements for structural fasteners in European projects should be checked before price negotiation, not after shipment. The buyer should confirm the applicable EN standard, assembly type, CE marking requirement, Declaration of Performance, traceability, coating, and inspection documents.<\/p>\n\n\n\n<p>For European structural work, the safest approach is simple: define the standard first, then quote the fastener.<\/p>","protected":false},"excerpt":{"rendered":"<p>For European steel construction projects, structural fasteners are not treated like ordinary hardware. If a bolt assembly is used in a regulated structural application, buyers must check whether CE marking, Declaration of Performance, and the correct EN standard apply. This is where many importers make mistakes. They ask for \u201c8.8 structural bolts\u201d or \u201cDIN bolts [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[479],"tags":[497],"class_list":["post-6573","post","type-post","status-publish","format-standard","hentry","category-fastener-knowledge-library","tag-fastener-standards-cross-reference"],"acf":[],"_links":{"self":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/6573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/comments?post=6573"}],"version-history":[{"count":1,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/6573\/revisions"}],"predecessor-version":[{"id":6574,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/6573\/revisions\/6574"}],"wp:attachment":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/media?parent=6573"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/categories?post=6573"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/tags?post=6573"}],"curies":[{"name":"\u53ef\u6e7f\u6027\u7c89\u5242","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}