{"id":9158,"date":"2026-11-26T10:17:47","date_gmt":"2026-11-26T02:17:47","guid":{"rendered":"https:\/\/xzfastener.com\/?p=9158"},"modified":"2026-11-26T10:17:50","modified_gmt":"2026-11-26T02:17:50","slug":"fastener-liquid-penetrant-inspection-order-scope","status":"publish","type":"post","link":"https:\/\/xzfastener.com\/zh\/fastener-liquid-penetrant-inspection-order-scope\/","title":{"rendered":"Liquid Penetrant Inspection for Fasteners: Define the Order Scope"},"content":{"rendered":"<style>.xz-purchase-guide{width:100%;max-width:900px;margin:0 auto;line-height:1.8;overflow-wrap:anywhere;box-sizing:border-box}.xz-purchase-guide h2{font-size:26px;line-height:1.4;margin:28px 0 14px}.xz-purchase-guide p{margin:0 0 18px}.xz-purchase-guide li{margin:8px 0}.xz-purchase-guide a{text-decoration:underline}@media(max-width:767px){.xz-purchase-guide{padding-right:44px}.xz-purchase-guide h2{font-size:22px}.xz-purchase-guide ul{padding-left:20px}}<\/style>\n<div class=\"xz-purchase-guide\">\n<p>\u201cDye penetrant test required\u201d leaves several purchasing decisions open. A useful order identifies the surfaces to examine, when the examination takes place and which criteria the inspector will use to evaluate indications. This is a separate deliverable from a visual inspection photograph.<\/p>\n<h2>State the examination purpose<\/h2>\n<p>Liquid penetrant examination is used to reveal discontinuities open to an accessible surface. It does not establish that the interior of a stud is free from discontinuities. Ask the engineering owner which possible discontinuities the examination is intended to address and whether the proposed method is appropriate for the material, geometry and surface condition.<\/p>\n<h2>Mark the coverage on the component drawing<\/h2>\n<p>Identify whether coverage includes thread roots, the head-to-shank transition, machined grooves, ends or another defined area. Record exclusions where the geometry prevents meaningful examination. Specify whether all parts or an agreed sample is examined, how samples are selected and what happens when a reportable indication is found. Avoid interpreting \u201c100% inspection\u201d as complete access to every surface without reviewing the actual part.<\/p>\n<h2>Agree the process and acceptance separately<\/h2>\n<p>Name the required examination practice and edition, then identify the separate acceptance document or approved criteria. A process reference alone need not supply the project acceptance limits. Let qualified inspection personnel prepare the procedure and resolve surface preparation, cleaning and inspection sequence with engineering. Do not add grinding or other surface alteration to remove indications without an approved disposition.<\/p>\n<h2>Request a usable inspection record<\/h2>\n<p>The report should identify the purchase order, part revision, batch, sample or individual part, examined areas, procedure, examination stage and outcome. Agree how indications are located and recorded, who evaluates them and who releases the batch. If cleaning or finishing follows the examination, identify the subsequent operations and any required re-examination. Keep rejected and pending parts physically distinguishable from released material.<\/p>\n<h2>Prepare the enquiry<\/h2>\n<p>Attach the marked coverage drawing and acceptance reference to the RFQ. Ask the supplier to disclose inspection exclusions, subcontracted work and the proposed report format before a price is treated as technically comparable.<\/p>\n<p>Send the drawing revision, material specification, quantities and destination to <a href=\"https:\/\/xzfastener.com\/zh\/home\/contact-us\/\">XZ Fastener for a quotation review<\/a>. Identify any material inspection report, dimensional report, batch traceability, EN 10204 3.1\/3.2 or third-party report required. The applicable scope, issuing parties and approval requirements need agreement before the order.<\/p>\n<p>Related purchasing guidance: <a href=\"https:\/\/xzfastener.com\/zh\/fastener-inspection-hold-witness-point-rfq\/\">Planning inspection hold and witness points<\/a>.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u201cDye penetrant test required\u201d leaves several purchasing decisions open. A useful order identifies the surfaces to examine, when the examination takes place and which criteria the inspector will use to evaluate indications. This is a separate deliverable from a visual inspection photograph. State the examination purpose Liquid penetrant examination is used to reveal discontinuities open [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[109],"tags":[],"class_list":["post-9158","post","type-post","status-publish","format-standard","hentry","category-technical-guides"],"acf":[],"_links":{"self":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/9158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/comments?post=9158"}],"version-history":[{"count":1,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/9158\/revisions"}],"predecessor-version":[{"id":9159,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/posts\/9158\/revisions\/9159"}],"wp:attachment":[{"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/media?parent=9158"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/categories?post=9158"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/xzfastener.com\/zh\/wp-json\/wp\/v2\/tags?post=9158"}],"curies":[{"name":"\u53ef\u6e7f\u6027\u7c89\u5242","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}